DRAFT
14. MALFUNCTION CODE
Field Service
V
er. 1.0 Feb. 2010
204
0062
Tray 3 media feed motor
malfunction
• The motor lock signal remains HIGH for a given period of
consecutive time while the media feed motor is being
rotated.
0063
Tray 4 media feed motor
malfunction
• The motor lock signal remains HIGH for a given period of
consecutive time while the media feed motor is being
rotated.
0094
2nd image transfer
pressure / retraction
failure
• The IDC sensor does not come into the condition where
the level detection is available (retracted position = IDC
sensor shutter is open) within a given period of time after
the 2nd transfer release solenoid has turned ON.
• The IDC sensor does not come into the condition where
the level detection is not available (pressed position = IDC
sensor shutter is closed) within a given period of time after
the 2nd transfer release solenoid has turned ON.
0096
1st image transfer
pressure / retraction
failure
• The 1st transfer release sensor is not activated (retracted
position) within a given period of time after the 1st transfer
release solenoid has turned ON.
• The 1st transfer release sensor is not deactivated (pressed
position) within a given period of time after the 1st transfer
release solenoid has turned ON.
0300
Polygon motor
malfunction
• The polygon motor does not rotate evenly even after the
lapse of a given period of time after it has been started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the polygon motor is being rotated.
0310
Laser malfunction
• The SOS signal is not detected within a given period of
time after the output of the laser has been started.
0500
Heating roller warm-up
failure
• The thermistor /1 does not detect the specified tempera-
ture and the warm-up cycle is not completed even after the
lapse of a given period of time after the cycle has been
started.
0502
Thermistor open-circuit
failure
• The temperature detected by the thermistor/1 does not
reach a predetermined level even after the lapse of a given
period time after the warm-up cycle has been started.
0503
Thermistor resistance
failure
• The difference between the temperature detected by ther-
mistor/1 and that detected by thermistor/2 exceeds a pre-
determined value.
0510
Abnormally low heating
roller temperature
• The temperature detected by the thermistor /1 remains
lower than the specified value for a given period of time or
longer.
0520
Abnormally high heating
roller temperature
• The temperature detected by the thermistor /1 remains
higher than the specified value for a given period of time or
longer.
• The heater lamp remains ON for a given period of time or
longer.
Code
Description
Detection timing
Summary of Contents for bizhub C35
Page 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Page 3: ...DRAFT ii Blank Page ...
Page 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Page 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Page 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Page 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Page 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...