DRAFT
16. IMAGE QUALITY PROBLEM
Field Service
V
er. 1.0 Feb. 2010
226
16.2.3
Scanner system: color spots
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C509DA
AA
AA
Step
Section
Check item
Result
Action
1
Original
Original is damaged or dirty.
YES
Change original.
2
ADF
Original pad is dirty.
YES
Clean.
3
Original glass
Original glass is dirty.
YES
Wipe the surface clean with a
soft cloth.
4
The problem has been eliminated
through the checks of steps up to 3.
NO
Change scanner unit.
Change MFPB.