DRAFT
14. MALFUNCTION CODE
Field Service
V
er. 1.0 Feb. 2010
208
14.4.3
0018: Developing motor malfunction
14.4.4
0045: MFP board cooling fan motor malfunction
Relevant electrical parts
Developing motor (M1)
Print control board (PRCB)
Step
Action
WIRING DIAGRAM
Control signal
Location (electri-
cal component)
1
Check the connector between M1-PRCB
PJ5 for proper connection and correct as
necessary.
-
-
2
Check the M1 connector for proper drive
coupling and correct as necessary.
-
-
3
M1 operation check
PRCB PJ5-10 to 13
B-15
4
Change M1.
-
-
5
Change PRCB.
-
-
Relevant electrical parts
MFP board cooling fan motor (FM12)
Printer control board (PRCB)
Step
Action
WIRING DIAGRAM
Control signal
Location (electri-
cal component)
1
Check the connector between FM12-relay
CN64-PRCB PJ14 for proper connection
and correct as necessary.
-
-
2
Check the fan for possible overload and
correct as necessary.
-
-
3
FM12 operation check
PRCB PJ14-7 (REM)
PRCB PJ14-9 (LOCK)
H-15
4
Change FM12.
-
-
5
Change PRCB.
-
-
Summary of Contents for bizhub C35
Page 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Page 3: ...DRAFT ii Blank Page ...
Page 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Page 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Page 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Page 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Page 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...