![Konica Minolta bizhub C35 Service Manual Download Page 195](http://html.mh-extra.com/html/konica-minolta/bizhub-c35/bizhub-c35_service-manual_1993461195.webp)
DRAFT
10. SER
V
ICE MODE
Field Service
V
er. 1.0 Feb. 2010
156
ADJUSTMENT
/
SETTING
10.9.4
Element Page
A. Use
• To print the engine element data information.
• To check the element data.
• See the attached chart listed below for details.
B. Procedure
1.
Call the Service Mode to the display.
2.
Touch [Print Menu]
→
[Element Page].
3.
Select [Print], and touch [OK].
C. Engine element data information
Element data name
Description
Inside Humidity
• Displays the inside humidity (in 1% increments).
INSIDE TEMPERATURE
• Displays the inside temperature (in 1 ºC increments).
PH TEMPRATURE
• Displays the PH temperature (in 1 ºC increments).
Sensor Information 1
• Displays the input port status of the sensors and switches in
hexadecimal numbers.
Sensor Information 2
Sensor Information 3
Sensor Information 4
Sensor Information 5
Fuser Heater 1 Temperature
• Displays the latest temperature on the middle of the heating roller
(in 1 ºC increments).
Fuser Heater 2 Temperature
• Displays the latest temperature at the edges of the heating roller
(in 1 ºC increments).
IDC Sensor 1 PS
• Shows the latest IDC data.
• Range of output: 0
V
to 9.99
V
(in 0.01
V
increments)
IDC Sensor 1 P
TONER LE
V
EL SENSOR C
• Displays the number of times the toner level sensor has detected
an empty condition during one cycle of developer agitation.
• Range of output: 0 to 200 (in increments of one time)
TONER LE
V
EL SENSOR M
TONER LE
V
EL SENSOR Y
TONER LE
V
EL SENSOR K
V
DC
V
olt C
• Displays the
V
dc voltage of each color of toner.
• Range of output: -1000
V
to 255
V
(in 1
V
increments)
V
DC
V
olt M
V
DC
V
olt Y
V
DC
V
olt K
V
PP
V
olt C
• Displays the
V
pp voltage of each color of toner.
• Range of output: 700
V
to 2000
V
(in 1
V
increments)
V
PP
V
olt M
V
PP
V
olt Y
V
PP
V
olt K
V
PP
V
olt Limit C
• Displays the limit value of
V
pp voltage of each color of toner.
• Range of output: 700
V
to 2000
V
(in 1
V
increments)
V
PP
V
olt Limit M
V
PP
V
olt Limit Y
V
PP
V
olt Limit K
Summary of Contents for bizhub C35
Page 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Page 3: ...DRAFT ii Blank Page ...
Page 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Page 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Page 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Page 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Page 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...