DRAFT
Field Service
V
er. 1.0 Feb. 2010
16. IMAGE QUALITY PROBLEM
229
bizhub C35
TROUBLESHOOTING
16.2.6
Scanner system: incorrect color image registration, sync shift (lines in
main scan direction)
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C512DA
AA
AA
AA
Step
Section
Check item
Result
Action
1
Original
Original does not lie flat.
YES
Change original.
2
ADF
ADF does not lie flat.
YES
Change ADF if it is deformed or
hinges are broken.
3
The problem has been eliminated
through the checks of steps up to 2.
NO
Change scanner unit.