14. MALFUNCTION CODE
203
bizhub C35
TROUBLESHOOTING
14. MALFUNCTION CODE
14.1 Trouble code (Service Call)
• The machine’s CPU performs a self-diagnostics function that, on detecting a malfunction,
gives the corresponding malfunction code on the control panel.
14.2 List
A121F4E503DA
Code
Description
Detection timing
0010
Color PC drum motor
malfunction
• The color PC drum motor does not rotate evenly even after
the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the color PC drum motor is being
rotated.
0017
Main motor malfunction
• The main motor does not rotate evenly even after the lapse
of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the main motor is being rotated.
0018
Developing motor
malfunction
• The developing motor does not rotate evenly even after the
lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the developing motor is being
rotated.
0045
MFP board cooling fan
motor malfunction
• The MFP board cooling fan motor does not rotate evenly
even after the lapse of a given period of time while it is
being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the MFP board cooling fan motor is
being rotated.
004A
Cooling fan motor
malfunction
• The cooling fan motor does not rotate evenly even after the
lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the cooling fan motor is being
rotated.
004E
DC power supply fan
motor malfunction
• The DC power supply fan motor does not rotate evenly
even after the lapse of a given period of time while it is
being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the DC power supply fan motor is
being rotated.
Summary of Contents for bizhub C35
Page 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Page 3: ...DRAFT ii Blank Page ...
Page 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Page 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Page 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Page 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Page 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...