3-20
3.3.4 Details
Memory switch 00x : Dialer
Memory switch 000 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Factory use only
—
6
0
Factory use only
—
5
0
CED detection condition
Sets whether the detection should be strict not.
Normal
Strict
350 ms 500 ms 700 ms 1000 ms
Switch 5
0
0
1
1
4
0
1
0
1
4
0
3
0
DIS detect time after dialing
0 : 55 sec
1 : 70 sec
Sets the DIS signal is detected after dialing a number.
2
1
CED detection
0 : No
1 : Yes
Can be use to ignore CED detection if noise on the telephone
line is mistaken as a 2100 Hz CED signal.
1
0
Factory use only
—
0
0
Phone line type for the first
phone line
0 : PSTN
1 : PBX
When set to PSTN, the machine checks for dial tone and acts
according to the setting of memory switch 000, bit "1" . When
set to PBX, the machine always dials a given number of sec-
onds after going off-hook. Memory switch 001 sets the number
of seconds.