![Konica Minolta bizhub 25e Field Engineering Manual Download Page 106](http://html1.mh-extra.com/html/konica-minolta/bizhub-25e/bizhub-25e_field-engineering-manual_1993091106.webp)
3-30
Memory switch 03x : Modem
Memory switch 030 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Number of HDLC end flags Defines the number of HDLC end flags.
Switch 7654
0000
1
0001
2
0010 3
Initial setting
0011
4
0100
5
0101
6
0110
7
0111
8
1000
9
1001
10
1010
11
1011
12
1100
13
1101
14
1110
15
1111
16
6
0
5
1
4
0
3
0
Factory use only
—
2
0
Factory use only
—
1
0
Digital cable equalizer
0 : Free
1 : Hold
When set to “1”, become efficient for the line short break, but
become weak for the line noise. It’s available only for commu-
nication at 14,400 or 12,000 bit/s.
0
0
Tone detection level
0 : -43 dBm
1 : -48 dBm
When set to “1”, detection level goes up but it becomes noise-
sensitive.
Adjust CED (2100 Hz) detection level in Unique switch 035.
Memory switch 031 :
bit
Initial
Setting
Adjust
Usage / Comments
7
1
EYE-Q check level at
7200 bps
0 0 1 1
Strict-- - - - - - - - - - - -Lenient
0 1 0 1
6
0
5
1
EYE-Q check level at
9600 bps
0 0 1 1
Strict-- - - - - - - - - - - -Lenient
0 1 0 1
4
0
3
1
EYE-Q check level at
12000 bps
0 0 1 1
Strict-- - - - - - - - - - - -Lenient
0 1 0 1
2
0
1
1
EYE-Q check level at
14400 bps
0 0 1 1
Strict-- - - - - - - - - - - -Lenient
0 1 0 1
0
0
Summary of Contents for bizhub 25e
Page 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Page 2: ......
Page 6: ...iv ...
Page 48: ...1 42 ...
Page 76: ...2 28 ...
Page 154: ...3 78 Second page of the report ...
Page 155: ...3 79 Third page of the report ...
Page 156: ...3 80 Fourth page of the report ...
Page 200: ...3 124 ...
Page 201: ...3 125 ...
Page 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Page 353: ......