2-17
2.3.11 Fusing mechanism
The toner image transferred on to the paper is securely fixed.
A heat roller system is used as the fusing system. The toner image is fused by heater roller heated by the
heater lamp, and securely fixed by the pressure between the heater roller and press rollers.
A thermistor detects and controls the heater roller temperature.
The thermostat functions when the heater lamp is not turned OFF even if the thermistor detects a high tem-
perature malfunction.
5
4
3
2
1
No.
Part name
No.
Part name
1
Scraper
2
Thermistor
3
Heater lamp
4
Heater roller
5
Press roller
Fusing temperature control circuit
The thermistor detects the surface temperature of the heater roller and inputs that analog voltage into the
main control board. Corresponding to this data, the heater lamp ON/OFF signal is output to the heater ON/
OFF switch of the power supply unit, causing the heater lamp to turn ON or OFF to control the fusing tem-
perature.
When the heater lamp is not turned OFF even if the thermistor detects a high temperature malfunction, the
first thermostat shuts down the power to the heater lamp. When the first thermostat is malfunction, the sec-
ond thermostat shuts down the power to the heater lamp.
N
L
Main Control PCB
Fusing temperature
control circuit
Power supply unit
AC Inlet
Fusing unit
Thermistor
Heater Lamp
Thermostat
Thermostat
Heater
on/off switch
Main switch
Summary of Contents for bizhub 25e
Page 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Page 2: ......
Page 6: ...iv ...
Page 48: ...1 42 ...
Page 76: ...2 28 ...
Page 154: ...3 78 Second page of the report ...
Page 155: ...3 79 Third page of the report ...
Page 156: ...3 80 Fourth page of the report ...
Page 200: ...3 124 ...
Page 201: ...3 125 ...
Page 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Page 353: ......