![Konica Minolta bizhub 25e Field Engineering Manual Download Page 102](http://html1.mh-extra.com/html/konica-minolta/bizhub-25e/bizhub-25e_field-engineering-manual_1993091102.webp)
3-26
Memory switch 01x : Transmission
Memory switch 015 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Program individual autodi-
aler attributes
0 : No
1 : Yes
Allows individual setting of memory switches 010 as attribute
1, 011 as attribute 2, 012 as attribute 3 and 013 as attribute 4
when fax destination are programmed. (Refer to page 3-54 for
settings.)
6
0
Factory use only
—
5
0
Factory use only
—
4
0
Factory use only
—
3
0
Factory use only
—
2
0
Sending RTC signal when
transmission is canceled
0 : Yes
1 : No
RTC signal is sent at the end of the transmission.
When set at “0”, the machine will send the RTC if the transmis-
sion is canceled. No error will occur.
When set at “1”, an error will occur because RTC will not be
sent at the end of a canceled transmission.
1
1
Cancel redial if T.4.1 or
T.4.4 error occurs
0 : Yes
1 : No
When set at “0”, if a T.4.1 or T.4.4 error occurs, the machine
will not retry the transmission.
0
1
Action after EOR signal
0 : Continue
1 : Discontinue
Sets action after receiving PPR four times at 2400 bps.
Memory switch 016 :
bit
Initial
Setting
Adjust
Usage / Comments
7
0
Factory use only
—
6
0
Factory use only
—
5
0
Factory use only
—
4
0
Disable DCS -bit 44 at Fine
and Normal transmission
0: Enable
1: Disable
This avoid a trouble that a PC-FAX stretches to the vertical
direction when the other party has received it.
Use only when trouble has occurred.
3
1
Additional data on TTI
transmit
0 : No
1 : Yes
When set at “0”, the transmission of the additional data (time,
the number of pages, file number, etc) is disabled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
2
1
Subscriber ID transmit
0 : No
1 : Yes
When set at “0”, the transmission of the subscriber ID is dis-
abled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
1
1
TTI (name) transmit
0 : No
1 : Yes
When set at “0”, the transmission of the name which was
stored in the unit is disabled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
0
0
Factory use only
—
Summary of Contents for bizhub 25e
Page 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Page 2: ......
Page 6: ...iv ...
Page 48: ...1 42 ...
Page 76: ...2 28 ...
Page 154: ...3 78 Second page of the report ...
Page 155: ...3 79 Third page of the report ...
Page 156: ...3 80 Fourth page of the report ...
Page 200: ...3 124 ...
Page 201: ...3 125 ...
Page 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Page 353: ......