4-18
Scan to FTP server and DocIndex transmission result
Error
Code
Description
Check message
Detail
Countermeasure
Description
10002
9999
System error
System error occurred.
An error occurred because
there was a temporary sys-
tem memory shortage.
Retry later.
9000
17
Connection error
Not able to be connected
Name resolution failed
•CheckDNSserveraddressis
set correct at "TCP/IP settings".
•CheckthatthedestinationFTP
server name is registered on
DNS server.
Invalid service call
33
Invalid IP address
56
TCP access error
210
Network error
211
No connection to FTP server
212
Connected to FTP server
213
Cannot open by FTP client
214
Open by FTP client
219
Received replay other than 22x from server
10
File read and write error
Not come by the file reading
and writing.
Cannot send a file when the
destination FTP server is
write protected.
Check that the destination FTP
server is not write protected.
Open type invalid
217
Replay including 1xx from server
218
Replay including 2xx from server
221
Replay including 3xx from server
7
Login error
Not able to log in.
Cannot login with the entered
user name and password.
Check that the entered user
name and password are correct.
PointerofinvalidFTP,usernameorpassword
220
Replay including 23x from server
222
Replay including 33x from server
Summary of Contents for bizhub 25e
Page 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Page 2: ......
Page 6: ...iv ...
Page 48: ...1 42 ...
Page 76: ...2 28 ...
Page 154: ...3 78 Second page of the report ...
Page 155: ...3 79 Third page of the report ...
Page 156: ...3 80 Fourth page of the report ...
Page 200: ...3 124 ...
Page 201: ...3 125 ...
Page 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Page 353: ......