3-52
Unique Switch 01x : Transmission
Unique Switch 010 :
Switch
Initial
Setting
Adjust
Usage/Comments
7
1
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Including TTI inside the
document
0: No
1: Yes
Setting this bit to “0” transmit the document length
added with the TTI. Setting it to “1” transmit the
length including TTI inside the document. However
in this case, the image at the top of the document
might be overlapped with TTI.
(TTI length: 4.2mm)
2
0
Factory use only
1
1
The number of times PPR is detected during ECM transmission
1 time 2 times 3 times 4 times
0
1
0 0 1 1
0 1 0 1
Unique Switch 011 ~ 012 — Factory use only
Unique Switch 013 :
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
1
Factory use only
5
0
Factory use only
4
1
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Encoding method for
transmission
Specify the encoding method.
bit
1 0
1 1
MMR
1 0
MR
0 1
MH
0 0
Machine capability (default)
0
0
Unique Switch 014 — Factory use only
Summary of Contents for bizhub 25e
Page 1: ...bizhub 25e FIELD ENGINEERING MANUAL version 1 May 2013 DD1 91200 60 ...
Page 2: ......
Page 6: ...iv ...
Page 48: ...1 42 ...
Page 76: ...2 28 ...
Page 154: ...3 78 Second page of the report ...
Page 155: ...3 79 Third page of the report ...
Page 156: ...3 80 Fourth page of the report ...
Page 200: ...3 124 ...
Page 201: ...3 125 ...
Page 325: ...5 75 4 Install the ASSY SCRAPER 5 to the Drum unit 6 5 6 ...
Page 353: ......