OPERATION
EXPLANATION OF COMPONENTS
97
REMARK
The flow can be adjusted for the attachment installed.
●
When the working mode is B mode
1.
Press select switch (9) and the normal screen on the monitor
display changes to the flow setting screen shown in the dia-
gram on the right.
2.
Press up switch (7) or down switch (8) to adjust to the desired
flow.
3.
After completing the flow setting, press input confirmation
switch (9).
4.
With the operation in Step (3), the flow setting screen
changes to the fine flow adjustment screen shown in the dia-
gram on the right.
5.
Press up switch (7) or down switch (8) to adjust to the desired
flow.
6.
After completing the flow setting, press input confirmation
switch (9).
The monitor display will return to the normal screen.
5. UNDO SWITCH
Pressing switch (5) whilst in the monitor menu screens, will return
you back to the previous screen displayed.