MAINTENANCE
SERVICE PROCEDURE
251
3.
Remove any dirt or dust that is accumulated in the evacuator
valve installed to cover.
4.
Direct dry compressed air (less than 0.69 MPa (7 kgf/cm
²
) to
the outer element from inside along its folds, then direct it
from outside along its folds and again from inside.
❍
Remove one seal from the element whenever the ele-
ment has been cleaned.
❍
Replace the outer element which has been cleaned 5
times repeatedly or used throughout a year. Replace the
inner element at the same time.
❍
Replace both inner and outer elements when the monitor
lamp (H) lights up soon after installing the cleaned outer
element even though it has not been cleaned 5 times.
❍
When replacing the element, new stick-on-seal is packed
in the same box as the element. Stick the seal in the posi-
tion.
5.
Remove the cloth or tape cover installed in Step 3.
6.
If small holes or thin cracks are found on the element when it
is checked by shining a light through it after cleaning, replace
the element.
NOTICE
●
When cleaning the element, do not hit or beat it against
anything.
●
Do not use an element whose folds or gasket or seal are
damaged.
Evacuator valve
Summary of Contents for PW160-7K Series
Page 2: ......
Page 3: ...3 FOREWORD ...
Page 14: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR FOREWORD 14 ...
Page 20: ...20 ...
Page 222: ...TROUBLESHOOTING OPERATION 222 ...
Page 304: ...SERVICE PROCEDURE MAINTENANCE 304 ...
Page 305: ...305 SPECIFICATIONS ...
Page 307: ...SPECIFICATIONS SPECIFICATIONS 307 1 PIECE BOOM ...
Page 308: ...SPECIFICATIONS SPECIFICATIONS 308 2 PIECE BOOM ...
Page 312: ...SPECIFICATIONS SPECIFICATIONS 312 ...
Page 354: ...ROTATING ARM OPTIONS ATTACHMENTS 354 ...
Page 357: ......