MAINTENANCE
SERVICE PROCEDURE
253
Air Cleaner Inner Element - Replace
1.
First remove the outer element, and then remove the inner
element.
2.
Cover the air connector side (outlet side) with a clean cloth or
tape.
3.
Clean the air cleaner body interior, then remove the cover
from the air intake port in Step 2.
4.
Install a new inner element to the connector, then tighten the
nut.
NOTICE
The inner element must not be cleaned and used again.
When replacing the outer element, replace the inner element
at the same time.
5.
Set the outer element in position, then lock cover (6) with
hooks (2).
6
2
Top
GL
Evacuator valve