Section 6 Component Testing and Adjustment
discoloration) indicate a stator in good condition.
See Figure 6-7.
Leads
Continuity
1 and 2
Yes
1 and 11
2 and 11
3 and 4
3 and 44
4 and 44
55 and 66
1 and 3, 4, 44, 55, or 66
No
2 and 3, 4, 44, 55, or 66
3 and 1, 2, 11, 55, or 66
4 and 1, 2, 11, 55, or 66
Any stator lead and ground on stator
housing or frame laminations
Figure 6-7
Continuity Test Results on a Good Stator
(single-phase)
Leads
Continuity
1 and 4
Yes
2 and 5
3 and 6
7 and 10
8 and 11
9 and 12
55 and 66
1 and 2, 3, 7, 8, or 9
No
1 and 55
Any stator lead and ground
Figure 6-8
Continuity Test Results on a Good Stator
(3-phase)
8. If the resistance test proves inconclusive, use a
megohmmeter to test the stator as described in the
next step.
Note:
Because
ohmmeter
accuracy
varies,
resistance
readings
are
approximate
readings. Take readings of the rotor and
stator at room temperature.
Note:
Make sure that all stator
leads are
disconnected
before
running
the
megohmmeter test.
9. Use a megohmmeter to determine whether the
stator is shorted to ground.
a. Apply 500 volts DC to any stator lead and the
stator frame. Perform the megohmmeter test
following the instructions of the megohmmeter
manufacturer.
b. Repeat the test on the other stator leads until
each coil is tested.
Note:
A reading of approximately 500 kOhms
(1/2 megohm) and higher indicates a
good stator.
c. Repair or replace the stator if any reading is
less than approximately 500 kOhms. A reading
of less than 500 kOhms indicates deterioration
of the winding insulation and possible current
flow to ground.
Summary of Contents for 12RES
Page 2: ......
Page 6: ...TP 6196 10 09 6 Notes ...
Page 34: ...TP 6196 10 09 34 Section 3 Troubleshooting Notes ...
Page 52: ...TP 6196 10 09 52 Section 4 ADC 2100 and DC 2200 Controllers Notes ...
Page 72: ...TP 6196 10 09 72 Section 5 ADC RES and DC RET Controller Notes ...
Page 100: ...TP 6196 10 09 100 Section 6 Component Testing and Adjustment Notes ...
Page 131: ......