TP-6196 10/09
15
Section 1 Specifications
1.6 Alternator Specifications
Alternator Specification
8.5/12 kW 1 phase
12TRES 3 phase
Frequency Hz
50/60
50
Phase
Single-Phase
Three
Number of leads
4
12
Excitation method
Static Excited
Voltage regulator type
Digital
Coupling type
Direct
Thrubolt torque, Nm ( ft. lb.)
40 (28)
Overbolt torque, Nm (in. lb.)
7 (60)
Insulation (rotor and stator)
Epoxy varnish, vacuum impregnated
Class 180 (H)
Winding material
Copper
Bearing, number and type
1, replaceable ball
Circuit protection
Controller
10 amps
Aux. winding
20 amps
Generator AC output
Dependent on voltage configuration
Rotor resistance, ohms, cold
4.0
4.2
Stator resistance, ohms,* cold
Single-Phase Leads 1-2, 3-4
0.07
N/A
Three-Phase Leads 1-4, 2-5, 3-6, 7-10, 8-11, 9-12
N/A
0.18
Leads 11-44
0.14
N/A
55-66
0.70
0.15
Stator output voltage with separately excited rotor using 12-volt
battery, minimum
Single-Phase Leads 1-2, 3-4
132 V
N/A
Three-Phase Leads 1-4, 2-5, 3-6, 7-10, 8-11, 9-12
N/A
115 V
11-44
264 V
N/A
55-66
145 V
150 V
Rotor field voltage/current readings at rated output voltage, hot
No load
12 V / 2.0 amps
14 V / 2.8 amps
Full load
47 V / 7.4 amps
78 V /11.5 amps
Brush length, new
19.05 mm (0.75 in.)
* Most ohmmeters do not give accurate readings when measuring less than 1 ohm. The stator can be considered good if a low resistance
reading (continuity) is obtained and there is no evidence of shorted windings (discoloration). Do not confuse a low resistance reading with
a reading indicating a shorted winding.
Summary of Contents for 12RES
Page 2: ......
Page 6: ...TP 6196 10 09 6 Notes ...
Page 34: ...TP 6196 10 09 34 Section 3 Troubleshooting Notes ...
Page 52: ...TP 6196 10 09 52 Section 4 ADC 2100 and DC 2200 Controllers Notes ...
Page 72: ...TP 6196 10 09 72 Section 5 ADC RES and DC RET Controller Notes ...
Page 100: ...TP 6196 10 09 100 Section 6 Component Testing and Adjustment Notes ...
Page 131: ......