2-8
ADJUSTING FOR THE PROPER FLAME
Flame
Adjustment
Screw
TRIPLETIER
CROWN BURNER
1.
Remove the control knobs from the five
gas valves.
2.
Remove the control panel from the front
panel (see page 4-2).
3.
Pull the rubber shield off the gas valve
stem.
4.
Turn on the power and gas and set the
inner and outer burner flames to the LO
setting.
5.
One at a time, insert a flat-blade screw-
driver into the slot in the external and
internal adjustment screws.Turn each of
the screws until the flame sizes are as
small as possible without going out.
6.
Quickly turn the gas valve from LO to
HI,and then back to LO.Both flames should
be on steady and not go out.
TripleTier
Burner
Internal Flame LO
Adjustment
TripleTier
Burner
External Flame
LO Adjustment
SURFACE BURNERS
1.
Turn on one of the surface burners and set
the flame to its lowest (LO) setting. The
flame should be steady and the inner cone
should be dark blue in color. The size
should be approximately 1/4
″
(0.64 cm)
high.
2.
If the low flame needs to be adjusted:
a) Remove the control knob.
b) Look inside the gas valve stem and note
the small screw. Insert a small screw-
driver into the gas valve stem and fit it
in the screw slot.
c) Hold the gas valve stem with a pair of
pliers, and turn the screw in either di-
rection until the flame size is approxi-
mately 1/4
″
high.
d) Replace the control knob.
e) Turn the control knob from HI to LO and
check to make sure that it remains ad-
justed properly.
f) Check the other three burners, and ad-
just them, if necessary.
Summary of Contents for KGRA806P
Page 12: ...1 8 NOTES ...
Page 24: ...2 12 NOTES ...
Page 26: ...3 2 NOTES ...
Page 56: ...4 30 NOTES ...
Page 65: ...5 9 Display Board Connector Pinouts Low Voltage Transformer ...
Page 66: ...5 10 Power Board ...
Page 68: ...5 12 Low Voltage Transformer Display Board Connector Pinouts ...
Page 69: ...5 13 Power Board ...
Page 70: ...5 14 NOTES ...
Page 82: ...7 6 NOTES ...
Page 84: ......