5-4
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HALO
BROIL ELEMENT
Refer to page 4-14 for the procedure for servic-
ing the Halo
broil element.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the Halo
broil element terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
Halo
broil element terminals. The meter
should indicate between 10 and 14
Ω
.
POWER SUPPLY TRANSFORMER
Refer to page 4-8 for the procedure for servic-
ing the power supply transformer.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect the transformer primary and
secondary wire connectors.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the two
primary connector pins. The meter should
indicate between 10 and 20
Ω
.