5-7
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
GAS DISTRIBUTION VALVE
Refer to page 4-23 for the procedure for ser-
vicing the gas distribution valve.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Remove the storage drawer.
NOTE:
You
can access the gas distribution valve from
inside the drawer area.
4.
Disconnect the wires from the gas distri-
bution valve terminals.
5.
Set the ohmmeter to the R x 1 scale.
6.
Touch the ohmmeter test leads to the
indicated gas distribution valve terminals.
The meter should indicate as follows:
Terminal 1 (red) to terminal 2 (orange)
= 216
Ω
±
30.
Terminal 2 (orange) to terminal 3 (blue)
= 216
Ω
±
30.
Orange
Blue
Red
OVEN TOD
Refer to page 4-22 for the procedure for ser-
vicing the oven TOD.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the oven
TOD terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
oven TOD terminals. The meter should
indicate a closed circuit (0
Ω
).
Summary of Contents for KGRA806P
Page 12: ...1 8 NOTES ...
Page 24: ...2 12 NOTES ...
Page 26: ...3 2 NOTES ...
Page 56: ...4 30 NOTES ...
Page 65: ...5 9 Display Board Connector Pinouts Low Voltage Transformer ...
Page 66: ...5 10 Power Board ...
Page 68: ...5 12 Low Voltage Transformer Display Board Connector Pinouts ...
Page 69: ...5 13 Power Board ...
Page 70: ...5 14 NOTES ...
Page 82: ...7 6 NOTES ...
Page 84: ......