4-21
REMOVING THE COOLING FAN
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Pull the range out of its mounting location
so that you can access the rear of the unit.
4.
Remove the rear panel from the unit (see
page 4-12 for the procedure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Cooling Fan
6.
Remove the four screws from the cooling
fan and remove the fan from the bracket.
5.
Use a 90
°
screwdriver, and remove the
two screws from each end of the cooling
fan cover, then remove the cover.
7.
Disconnect the two cooling fan wires from
the motor terminals.
Cooling Fan
Cover
Screws
(2 of 4)
Cooling Fan Screws
Motor Wires