2-4
NOTE:
The L.P. orifices are fastened to the
back of the range near the bottom on a card-
board form.
Orifice Card
1.
Check to make sure that the main gas
supply line to the range has been shut off,
and that the power supply cord is discon-
nected from the AC outlet.
2.
To convert the surface burners for use
with L.P. gas:
a) Remove the grates and burner caps
from the cooktop.
b) Remove the two screws from each of
the burner heads and lift the heads off
the cooktop.
Burner Head
Gas Valve Handle
To “Shutoff” Position
L.P. GAS CONVERSION
NOTE: Gas conversion from Natural to L.P.
gas must be done by a qualified installer.
Examples of a qualified installer include
licensed heating personnel, authorized gas
company personnel, and authorized ser-
vice personnel.
L.P. gas must not be used unless the L.P.
conversion has been made using the kit that is
included with this range. See the “Gas Supply
Requirements” starting on page 2-1.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning
gas supply valve back on.
Failure to follow these instructions
could result in explosion, fire, or other
injury.
WARNING
Summary of Contents for KGRA806P
Page 12: ...1 8 NOTES ...
Page 24: ...2 12 NOTES ...
Page 26: ...3 2 NOTES ...
Page 56: ...4 30 NOTES ...
Page 65: ...5 9 Display Board Connector Pinouts Low Voltage Transformer ...
Page 66: ...5 10 Power Board ...
Page 68: ...5 12 Low Voltage Transformer Display Board Connector Pinouts ...
Page 69: ...5 13 Power Board ...
Page 70: ...5 14 NOTES ...
Page 82: ...7 6 NOTES ...
Page 84: ......