4-23
REMOVING THE GAS DISTRIBUTION VALVE
4.
Disconnect the gas lines from the gas
distribution valve.
5.
Remove the four screws from the gas
distribution valve, pull it down to remove
the orifice from the bake burner, and lay it
down so you can access the wires.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Pull the range out of its mounting location
so that you can access the rear of the unit.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Gas Distribution Valve
6.
Disconnect the three wires from the gas
distribution valve terminals.
Gas Outlet Lines
Screws (2 of 4)
Gas Inlet Line
Red
Orange
Blue
Oven Shutoff Valve
NOTE:
For servicing the Gas Distribution Sys-
tem, refer to Job Aid
KR-28
, Part Number
8177893
.