6-1
DIAGNOSTICS & TROUBLESHOOTING
DIAGNOSTICS
O . BROIL REL CYCLED
Relay Being
Engaged
Latch
Switch
Meat Probe
Readout*
Warming Drawer
Sensor Readout*
#2 Oven Temp
Sensor Readout*
#1 Oven Temp
Sensor Readout
Version
Door
Switch
F
Code
E
Code
AM34 UI30 EEKET - 002
72
73
73
F
0
0
* If available (3 dashes will be shown if not available)
DOUBLE LINE BREAK (DLB), FANS, AND OPEN DOOR
During diagnostics, all fans and elements may operate with the door open.
NOTE:
The latch motor
will not cycle with the door open.
On electric models, the double line break (DLB) will engage when entering the diagnostics mode,
and will disengage when exiting the diagnostics mode.
ENTERING MANUAL DIAGNOSTICS
Within 120 seconds of power up, press the following keys to enable the relay capabilities listed
below, and enter the manual diagnostics mode:
a
Cancel
key.
b)
Cancel
key.
c)
Start
key.
ENGAGING THE RELAYS
Pressing the following keys will toggle the state of the associated relays.
NOTE:
For the latch
relay, the self-clean button will turn on the latch relay, and changing the state of the latch switch
will turn off the relay.
Key Press
Relay
Text Line Display
Bake Key
Bake Relay
BAKE RELAY CYCLED
Maxi Broil Key
Outer Broil Relay
O.BROIL REL CYCLED
Econo Broil Key
Inner Broil Relay
I.BROIL REL CYCLED
Convect Bake
Conv Relay and Fan
CONV REL CYCLED
Warm Drawer On Warm Drawer Relay
WD RELAY CYCLED
Top Light
Oven Light Relay
O LIGHT REL CYCLED
Oven Light
Top Light Relay
T LIGHT REL CYCLED
Clean Key
Cycle Motor
ROTATING MOTOR
After Latch Sw Toggles
MOTOR ROTATED
Summary of Contents for KGRA806P
Page 12: ...1 8 NOTES ...
Page 24: ...2 12 NOTES ...
Page 26: ...3 2 NOTES ...
Page 56: ...4 30 NOTES ...
Page 65: ...5 9 Display Board Connector Pinouts Low Voltage Transformer ...
Page 66: ...5 10 Power Board ...
Page 68: ...5 12 Low Voltage Transformer Display Board Connector Pinouts ...
Page 69: ...5 13 Power Board ...
Page 70: ...5 14 NOTES ...
Page 82: ...7 6 NOTES ...
Page 84: ......