28
PLZ-4WL
Turning the Load On and Off
Turning the load off
1
Press LOAD to turn off the load.
2
Turn off the output of the DUT. If you are using a relay, electromagnetic
switch, or other device in the connection between the load input
terminals and the output terminals of the DUT, turn the device off.
■
Turning the load off after a specified amount of time
The function for turning the load off after a specified period of time is convenient for discharge
testing of batteries and capacitors. By factory default, the load on timer is off.
To turn the load on timer on, from the menu, select “1. Setup” > “4. Cut Off” > “Time,” and set
the time. Turn the power switch off and then on again to enable the settings.
When the load turns off, a popup window appears indicating the input voltage at the time the
load was turned off.
See