PLZ-4WL
133
Sequence Program Creation Table
App.
Entry example
Program name: Example sequence of chapter 6: PLZ164W
Date:
By:
Program number
(1 to 10)
1
Memo
(Up to 11 characters)
Program1
Operation mode
CC,
Range
Current (A) -- Voltage (V)
50 (A) -- 30 (V)
Loop (1 to 9999)
0001
Last Load (OFF/ON)
OFF,
Last Set
0
Chain (OFF, 1 to 10)
2
Step number
Setting
(mA, mS, V, W)
Execution time
(h:min:s:ms)
LOAD
RAMP
TRIG
PAUSE
Note
1
7 A
200 s
ON
ON
OFF
OFF
2
7 A
150 s
ON
OFF
OFF
OFF
3
0.5 A
80 s
OFF
OFF
OFF
OFF
Program name: Example sequence of chapter 6: PLZ164W
Date:
By:
Program number
(1 to 10)
2
Memo
(Up to 11 characters)
Program2
Operation mode
CC
Range
Current (A) -- Voltage (V)
50 (A) -- 30 (V)
Loop (1 to 9999)
0002
Last Load (OFF/ON)
OFF
Last Set
0
Chain (OFF, 1 to 10)
OFF
Step number
Setting
(mA, mS, V, W)
Execution time
(h:min:s:ms)
LOAD
RAMP
TRIG
PAUSE
Note
1
10 A
200 s
ON
ON
OFF
OFF
2
5 A
50 s
ON
OFF
OFF
OFF
3
8 A
150 s
ON
ON
OFF
OFF