PLZ-4WL
111
Specifications
7
S
pec
ifi
cati
ons
Switching mode
Slew rate
Model
PLZ164WL
PLZ334WL
Operation modes
CC and CR
Duty cycle
5 % to 95 %
1
in 1 % steps
1
The minimum time width is 10 µs. Between 5 kHz and 50 kHz, the maximum duty cycle is limited by the
minimum time width.
Frequency range
1 Hz to 50 kHz
Frequency
resolution
1 Hz to 10 Hz
0.1 Hz
10 Hz to 100 Hz
1 Hz
100 Hz to 1 kHz
10 Hz
1 kHz to 50 kHz
100 Hz
Frequency accuracy of setting
±(0.5 % of set )
Model
PLZ164WL
PLZ334WL
Setting range
1
1
Can only be set in constant current mode
H range
2.5 mA/µs to 25 A/µs
5 mA/µs to 50 A/µs
M range
250 µA/µs to 2.5 A/µs
500 µA/µs to 5 A/µs
L range
25 µA/µs to 250 mA/µs
50 µA/µs to 500 mA/µs
Resolution
(the setting ranges
are indicated in
parentheses)
H range
12.5 mA/µs
(250 mA/µs to 25 A/µs)
25 mA/µs
(500 mA/µs to 50 A/µs)
125 µA/µs
(2.5 mA/µs to 250 mA/µs)
250 µA/µs
(5 mA/µs to 500 mA/µs)
M range
1.25 mA/µs
(25 mA/µs to 2.5 A/µs)
2.5 mA/µs
(50 mA/µs to 5 A/µs)
12.5 µA/µs
(250 µA/µs to 25 mA/µs)
25 µA/µs
(500 µA/µs to 50 mA/µs)
L range
125 µA/µs
(2.5 mA/µs to 250 mA/µs)
250 µA/µs
(5 mA/µs to 500 mA/µs)
1.25 µA/µs
(25 µA/µs to 2.5 mA/µs)
2.5 µA/µs
(50 µA/µs to 5 mA/µs)
Accuracy of setting
2
2
The time it takes to shift from 10 % to 90 % when the current is varied from 2 % to 100 % (20 % to 100
% in the M range) of the rated current
±(10 % of set + 0.8 µs)