16
PLZ-4WL
Turning the Power On
When the PLZ-4WL does not start properly
This section introduces what measures you can take when the PLZ-4WL does not start
properly. If following the remedy shown here does not solve the problem, contact your Kikusui
agent or distributor.
Checking the version
You can check the firmware and ROM versions by selecting “1. Model Info” on the menu
screen.
Turning the POWER switch Off
Flip the POWER switch to the ( ) side to turn the PLZ-4WL off.
The PLZ-4WL saves the panel settings (except the load on/off setting) that were in use
immediately before the POWER switch was turned off. When you turn on the POWER switch,
the PLZ-4WL starts up with the saved settings. If the POWER switch is turned off immediately
after the settings have been changed, the last settings may not be stored.
Nothing is displayed.
Make sure that the power cord is connected
properly, and then turn the POWER switch on
again.
Adjusts the contrast of the display.
Abnormal current or voltage values are
being displayed.
Turn the PLZ-4WL POWER switch off and then on
again.
--
An alarm has occurred.
A protection function has been activated. Eliminate
all the cause of the alarm.
See
See
See
[ PLZ164
W
L ]
VERSION
SUB 1.00
MAIN 1.02
Firmware version
ROM version
PREV
Model Information
Example for the PLZ164WL.
CAUTION
After you turn the POWER switch off, wait at least 5 seconds after the fan stops before you
turn the POWER switch back on. Turning the PLZ-4WL on too soon after you turn it off can
cause damage to the inrush current limiter circuit, as well as reduce the life of components
such as the POWER switch and the internal input fuses.