Sequence Example (Normal Sequence)
4
Sequenc
es
Setting the steps of program 2
The settings will be configured in the same order as they were for program 1.
Memo
You can move the cursor
by pressing
,
,
,
and .
Press NEXT (SHIFT+
)
to move to the next
screen.
Press PREV (SHIFT+
)
to return to the previous
screen.
1
Set the currents for steps 1 to 3.
Set the current for step 1 to 10 A, for step 2 to 5 A, and for
step 3 to 8 A.
2
Set the execution times for steps 1 to 3.
Set the execution time for step 1 to 3 min 20 s; for step 2 to
50 s, and for step 3 to 2 min 30 s.
3
Set the execution patterns for steps 1 to 3.
For step 1, set LOAD to ON, RAMP to ON, TRIG to OFF, and
PAUSE to OFF. For step 2, set LOAD to ON, RAMP to OFF,
TRIG to OFF, and PAUSE to OFF. For step 3, set LOAD to ON,
RAMP to ON, TRIG to OFF, and PAUSE to OFF.
All the settings for program 2 have been entered.
4
Press PREV (SHIFT+) four times to exit the
sequence editing screen.
Each time you press PREV (SHIFT+), the previous screen is
displayed. Keep pressing PREV (SHIFT+ ) until the screen
that was displayed before you started sequence editing
appears.
SEQ EDIT
PREV
NEXT
001 10.000
A
CC SET
[
A
]
002 5.000
A
003 8.000
A
END
TOTAL 003
SEQ EDIT
PREV
NEXT
002 0:00: 5000
001 0:03: 20––
003 0:02: 30––
[
h : m i n : s . m s
]
END
TOTAL 003
SEQ EDIT
PREV
001 ON ON OFF OFF
002 ON OFF OFF OFF
003 ON ON OFF OFF
LOAD RAMP TRIG
PAUSE
END
TOTAL 003