34
PLZ-4WL
Constant Voltage Mode (CV mode)
In constant voltage mode (CV mode), you set the voltage [V].
Configuring CV mode
Select the operation mode, and set the voltage.
1
Make sure that the load is off.
The load is off when the LED to the upper left of the LOAD key is off. If the LED is lit,
press LOAD to turn the load off.
2
Press MODE to select the operation mode (CV).
The operation mode popup menu appears.
Press MODE repetitively until CV is highlighted on the menu. After you select the
operation mode, the popup menu disappears, and “CV” appears on the display.
3
Press RANGE to select the current range.
The current range popup menu appears.
Each time you press RANGE, the range switches between L, M, and H. Press RANGE
until the range that you want to select is highlighted. After you select a range, the
popup menu disappears, and the range that you selected appears along with its full
scale value. The full scale value varies depending on the model.
4
Press VRANGE (SHIFT+RANGE) to select the voltage range.
The voltage range popup menu appears.
Each time you press VRANGE (SHIFT+RANGE), the voltage range switches between
4 V and 30 V. After you select a voltage range, it appears on the display. Press
VRANGE (SHIFT+RANGE) until the range that you want to select is highlighted.
5
Check that the display is in the fundamental setting entry condition.
If SET is not highlighted, press SET/VSET to switch to the fundamental setting entry
condition.
6
Turn the rotary knob to set the voltage.
The CV mode settings are complete. When you press LOAD, the LOAD LED lights, and the
PLZ-4WL starts supplying current. You can change the voltage even when the load is on.
S
W
ITCHING
ENTER
SHORT
EDIT
SLE
W
RATE
RUN / STOP
UVP
PAUSE
STORE
RECALL
A
B
C
LOAD
Th/TL
FREQ / DUTY
MENU
PRESET SEQ
I
LEVEL
VRANGE
RANGE
S
W
ON
+CV
MODE
LOAD
SET / VSET
LOCK
SHIFT
ABC
OPP / OCP
Memo
When “SET” is
highlighted, the PLZ-4WL
is in the fundamental
setting entry condition.