PLZ-4WL
67
Sequence Example (Normal Sequence)
4
Sequenc
es
Setting the execution pattern
Memo
You can move the cursor
by pressing
,
,
,
and .
Press PREV (SHIFT+
)
to return to the previous
screen.
1
Press to move the cursor to step 001.
2
For step 1, set LOAD and RAMP to ON.
Press to move the cursor to the item that you want to
set.
Turn the rotary knob to choose a setting. Leave TRIG and
PAUSE set to OFF.
3
Press to move the cursor to step 002. For step 2,
set LOAD to ON.
Leave RAMP, TRIG, and PAUSE set to OFF.
4
Press to move the cursor to step 003. For step 3,
set TRIG to ON.
Leave LOAD, RAMP, and PAUSE set to OFF. All the settings
for program 1 have been entered. Next we will edit program
2.
SEQ EDIT
PREV
001 ON ON OFF OFF
002 ON OFF OFF OFF
003 OFF OFF ON OFF
LOAD RAMP TRIG
PAUSE
END
TOTAL 003