450
Keysight M8070A Programming Guide
5
SCPI Command Reference
This SCPI is applicable for M8041A and M8051A.
Example
:PLUGin:CCAPture:ACQuisition:HOLDoff ‘My Measurement’, 1
:PLUGin:CCAPture:ACQuisition:SOURce[?]
Syntax
:PLUGin:CCAPture:ACQuisition:SOURce ‘identifier’,<CINA | CINB | ERRor I
IMM>
:PLUGin:CCAPture:ACQuisition:SOURce? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
<CINA | CINB | ERRor | IMM>
Return Range
CINA | CINB | ERRor | IMM
Description
Specifies the event for triggering the compare & capture measurement.
CTRL IN A or CRTL IN B or an ERRor occurred can be chosen to trigger the
capture recording. IMM can be used to capture data without any trigger.
This SCPI is applicable for M8041A and M8051A.
Example
:PLUGin:CCAPture:ACQuisition:SOURce ‘My Measurement’,CINA
:PLUGin:CCAPture:ACQuisition:SLOPe[?]
Syntax
:PLUGin:CCAPture:ACQuisition:SLOPe ‘identifier’, <POS | NEG>
:PLUGin:CCAPture:ACQuisition:SLOPe? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
<POS | NEG>
Return Range
POS | NEG
Description
If CINA or CINB is selected for triggering the capture process this
command specifies the slope the trigger react with.
This SCPI is applicable for M8041A and M8051A.
Example
:PLUGin:CCAPture:ACQuisition:SLOPe ‘My Measurement’, POS