358
Keysight M8070A Programming Guide
5
SCPI Command Reference
:PLUGin:OLEVel:FETCh:QLEVel:QRBer?
Syntax
:PLUGin:OLEVel:FETCh:QLEVel:QRBer? ‘identifier’ [,‘Location’]
Input
Parameters
‘identifier’: Specify the measurement name.
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’ (optional).
Description
This command returns the value of the Q Residual BER.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example
:PLUGin:OLEVel:FETCh:QLEVel:QRBer? ‘MyMeasurement’
:PLUGin:OLEVel:FETCh:QLEVel:HIGH?
Syntax
:PLUGin:OLEVel:FETCh:QLEVel:HIGH? ‘identifier’ [,‘Location’]
Input
Parameters
‘identifier’: Specify the measurement name.
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’ (optional).
Description
This command returns the value of the Q High Level.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example
:PLUGin:OLEVel:FETCh:QLEVel:HIGH? ‘MyMeasurement’
:PLUGin:OLEVel:FETCh:QLEVel:HIGH:POINts?
Syntax
:PLUGin:OLEVel:FETCh:QLEVel:HIGH:POINts? ‘identifier’ [,‘Location’]
Input
Parameters
‘identifier’: Specify the measurement name.
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’ (optional).
Description
This command returns the value of the Q High Level Points.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example
:PLUGin:OLEVel:FETCh:QLEVel:HIGH:POINts? ‘MyMeasurement’