Keysight M8070A Programming Guide
445
SCPI Command Reference
5
:PLUGin:CCAPture:FETCh:PATTern[:DATA]:HOLDoff?
Syntax
:PLUGin:CCAPture:FETCh:PATTern[:DATA]:HOLDoff?
'identifier' [,‘Location’]
Input
Parameters
identifier: ‘Name of Measurement’
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’
Description
This command returns the actual holdoff i.e. number of data bits captured
before the trigger event. Returned value of this query is only valid when
capture measurement is finished.
This SCPI is applicable for M8041A and M8051A.
Example
:PLUGin:CCAPture:FETCh:PATTern:DATA:HOLDoff? 'MyMeasurement',
‘M1.DataIn1’
Return: (“M1.DataIn1”, ...)
:PLUGin:CCAPture:FETCh:PATTern[:DATA]:DEPTh?
Syntax
:PLUGin:CCAPture:FETCh:PATTern[:DATA]:DEPTh? 'identifier' [,‘Location’]
Input
Parameters
identifier: ‘Name of Measurement’
[,‘Location’]: ‘M*.DataIn1’ or ‘M*.DataIn2’
Description
This command returns the total number of data bits captured. Returned
value of this query is only valid when capture measurement is finished.
This SCPI is applicable for M8041A and M8051A.
Example
:PLUGin:CCAPture:FETCh:PATTern:DATA:DEPTh? 'MyMeasurement',
‘M1.DataIn1’
Return: (“M1.DataIn1”, ...)