BOP HIPWR 091719
3-27
TABLE 3-7. POWER UP SETTINGS MENU
PARAMETER
CHOICES
(
BOLD
= Factory Default)
FUNCTION
NOTE: DEFAULT values for empty cells are the settings of the unit at the time the save/recall menu is entered.
Mode of Operation
Voltage
Current
External
Voltage
- Selects voltage mode. Voltage value determined by SETTING.
Current
- Selects current mode. Current value determined by SETTING.
External
- Used for customized configuration where EXT VM/CM signal
at pin 2 of I/O port controls mode; consult factory for details.
Main Channel
Reference
Internal
External
ExtRefLevel
Internal
: Any external reference applied to the Analog I/O port pin 11 is
ignored and the internal reference is established by Main Setting field.
External
: The internal reference is ignored, and the external reference
applied to the Analog I/O port pin 11 is used (see PAR. 3.4.4.1).
ExtRefLevel
: Allows the gain of the BOP to be established by the maxi-
mum output voltage or current introduced by the Main Setting field. (see
PAR. 3.4.4.2).
Main Setting
0.0000
nn.nnn or
nnn.nnn
(model and parameter
dependent)
Sets the active channel setting. E.g., if Voltage mode is selected,
nnn.nnn is voltage setting, if Current mode is selected, nn.nnn is current
setting. If External mode is selected, Main Setting is not available. (This
value is visible only if Main Channel Reference is set to Internal or
ExtRefLevel and the Remote On-Off (which controls shutdown pin 2 of
the Trigger port) is not set to Disabled or LowPulseOff) (see PAR. 3.3.6
to view or modify Remote On-Off)
Protection
Type
Internal
External
Lesser Limit
Internal
- Allows limits to be controlled by POSITIVE and NEGATIVE
values.
External
: Allows limits to be controlled by analog signals applied to the
analog port (see PAR. 3.4.5).
Lesser
Limit
: Allows protect limit to be automatically selected from
either 1) the external analog voltage applied to the Analog I/O port or 2)
the value set in the Voltage Protect and Current Protect fields. Which-
ever limit has a lower absolute value (closest to zero) has effect (see
PAR. 3.4.5).
Voltage Level
nn.nnn or
nnn.nnn
This is the ± value for Voltage protect when the unit operates in Current
mode. If External mode is selected, this field is not accessible. To save
nonsymmetrical protect values for power up, modify Max/Min settings as
needed and press
$
to save for power up.
Current Level
nn.nnn or
nnn.nnn
This is the ± value for Current protect when the unit operates in Voltage
mode. If External mode is selected, this field is not accessible. To save
nonsymmetrical protect values for power up, modify Max/Min settings as
needed and press
$
to save for power up.
Output
OFF
ON
OFF
- Output disabled. The behavior of the unit when output is disabled
depends on the LOAD TYPE setting (see PAR.3.3.7).
ON
- Output enabled.
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......