BOP HIPWR 091719
3-77
FIGURE 3-27. TREE DIAGRAM OF SCPI COMMANDS USED WITH BOP POWER SUPPLY (SHEET 2 OF 2)
3.6.3.4
MEASURE SUBSYSTEM
This query subsystem returns the voltage and current measured at the power supply's output
terminals. Commands are provided to coordinate the rate and sequencing of the Measurement
System with Output System updates.
3.6.3.5
OUTPUT SUBSYSTEM
This subsystem controls the power supply's voltage and current outputs.
[SOURce:] subsystem
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] val
[:AMPLitude]? MIN, MAX
:TRIGgered
[:AMPLitude] val
[:AMPLitude]?
:LIMit[:BOTH]
[:BOTH]?
:NEGative
:NEGative?
:POSitive
:POSitive?
:MODE FIXed, LIST, TRANsient,
EXTernal, GAIN, PROTect
:MODE?
:PROTect
[:BOTH]
[:BOTH]?
:MODE INT, EXT, LESS
:MODE?
:NEGative
:NEGative?
:POSitive
:POSitive?
:LIM[:BOTH]
:LIM[:BOTH]?
:LIM:NEGative
:LIM:NEGative?
:LIM:POSitive
:LIM:POSitive?
ROOT :
(colon)
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] val
[:AMPLitude]? MIN, MAX
:TRIGgered
[:AMPLitude] val
[:AMPLitude]?
:LIMit[:BOTH]
[:BOTH]?
:NEGative
:NEGative?
:POSitive
:POSitive?
:MODE FIXed, LIST, TRANsient,
EXTernal, GAIN, PROTect
:MODE?
:PROTect
[:BOTH]
[:BOTH]?
:MODE INT, EXT, LESS
:MODE?
:NEGative
:NEGative?
:POSitive
:POSitive?
:LIM[:BOTH]
:LIM[:BOTH]?
:LIM:NEGative
:LIM:NEGative?
:LIM:POSitive
:LIM:POSitive?
FUNCtion
:MODE VOLT, CURR, EXTernal
:MODE?
:TRIGger VOLTage, CURRent
:TRIGger?
LIST subsystem
LIST
:CLEar
:COUNt val
:COUNt?
:COUNt:SKIP int
:COUNt:SKIP?
:CURRent val,val
APPLy type,val1,val2,val3
SWEep START, STOP
SWEep?
:POINts?
:CURRent?
:DIV val
:DIV?
:DWELl val,val
:DWELl?
:POINts?
:QUERy val
:QUERy?
:REP val1,val2,val3
:RES?
:SAMP:CURRent int,val
:SAMP:VOLTage int,val
:SAMP?
:SET:SAMPle val
:SET:SAMPle?
:SET:TRIGger val ON, OFF
:SET:TRIGger?
:SET:WAIT val
:SET:WAIT?
:TRIGger val
:VOLTage val,val
APPLy type,val1,val2,val3
SWEep START, STOP
SWEep?
:POINts?
:VOLTage?
:WAIT
:HIGH val
:LEDG val
:LOW val
Requires MEM:UPD to save for power-up.
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......