BOP HIPWR 091719
1-13
GENERAL (ENVIRONMENTAL) CHARACTERISTICS
Temperature
operating
0 to +50 deg C
Full rated load
storage
-20 to +85 deg C
Cooling
Two internal fans
exhaust to the rear
Humidity
0 to 95% RH
non-condensing
Shock
20g. 11mS ±50% half sine
non-operating
Vibration
5-10HZ:
10mm double amplitude
3 axes, non-operating
10-55HZ:
2g
3 axes, non-operating
Altitude
sea level to 10,000 feet
Safety Certification
a-c power
UL 3101-1 and EN 6101-1
Pending
PHYSICAL CHARACTERISTICS
Dimensions
English
5.25' X 19" X 21.5"
H X W X D
metric
133.3mm X 482.6mm X 546.1mm
H X W X D
Weight, 1000W models
English
53 lbs
metric
24.1Kg
Connections
Source power
3-pin IEC connector
Load connections
Nickel-plated copper bus bars
With 1/4-20 threaded standoff.
Sensing Output
Terminal Block
7-pin terminal block
Default: 3 links installed for local sensing and
ground network connected.
Analog I/O control port
15-pin D female
PAR/SER CTRL IN port
8-pin mini DIN connector
PAR/SER CTRL OUT port
4-pin mini DIN connector
PAR/SER PROT IN port
8-pin phone jack
PAR/SER PROT OUT port
8-pin phone jack
EXT PROT port
6-pin phone jack
See Table 2-4
Primary digital port
24-pin GPIB connector
IEEE 488 port - See Table 2-11
Secondary digital
ports
6-pin phone jack
RS 232 port - See Table 2-5
5-pin mini DIN female connector
IEEE 1118 port - See Table 2-2
External Trigger
4-pin stereo audio phone jack
See Table 2-3
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......