B-46
BOP-1K 091719
-240,“Hardware error”
Execution error bit 4
Power supply did not respond to command.
-241,”Hardware missing; External Reference not
supported”
Execution error bit 4
External Reference not supported.
-241,”Hardware missing; Bipolar limits not
supported”
Execution error bit 4
Bipolar limits not supported.
-242,”Voltage comparison error”
Execution error bit 4
Issued during Voltage calibration (Volt [zero, max,
min], voltage external protect, Voltage in series)
indicating the measurements are incorrect.
-243, “Current comparison error”
Execution error bit 4
Issued during Current Calibration (Current (max,
min or Zero, Current external limit, slave input)
indicating the measurements are incorrect.
-249,”Master Not Found”
Execution error bit 4
The slave controller for a multiple unit configura-
tion has not detected a master unit. - this is an
operator error as the slave should not be oper-
ated over the GPIB interface.
-311,”Memory Error”
Device Error bit 3
(1)
*SAV (save), *RCL (recall), MEMory:SAVE,
MEMory:UPDAte or CALibrate:STORe error
-314,”Save/recall Memory Lost”
Device Error bit 3
(1)
A memory location that was saved earlier was
lost due to a flash error in Analog processor mem-
ory.
-340,”Calibration Failed”
Device Error bit 3
(1)
The calibration results were invalid. This normally
indicates an incorrect calibration caused by oper-
ator error such as performing a current calibration
without a load,8 or a voltage calibration with a
load.
-350,”Queue Overflow”
Device Error bit 3
(1)
Error queue was full, error events have been lost.
-363,”Input buffer overrun”
Device Error bit 3
(1)
The input from the controlling computer was lon-
ger than 253 characters in length.
-370,”A2 External Error”
Device Error bit 3
(1)
Either external input error (A2A5 optocoupler) or
an A2 error occurred that could not be defined by
evaluating PAL latches.
-400,”QueryError”
Query Error bit 2
Data requested was lost due to 253 character
limit or BIT 4886 output buffer
-420,”Query Unterminated”
Query Error bit 2
Controller sent query but did not accept data from
power supply. See VOLT? (PAR. B.104),
CAL:SAVE (PAR. B.104) commands
-440,”Missing Query”
Query Error bit 2
Controller sent MEM:PACK, MEM:UPD,
SYST:SEC:IMM or SYST:SEC:OVER without pre-
ceding command with query or following the com-
mand with ;*OPC? (see PAR. 3.5.2.2 for details.)
TABLE B-6. ERROR MESSAGES (CONTINUED)
ERROR MESSAGE
ESR ERROR BIT SET
(SEE PAR. A.5)
EXPLANATION
(1)
The Device error bit may be set when the status monitoring functions of the power supply detect an overvoltage/under-
voltage condition.
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......