1-10
BOP HIPWR 091719
FUNCTION GENERATOR CHARACTERISTICS (Continued)
Waveform graphics displayed on LCD for both
Local and Remote operation
Local: The LCD represents the programming waveform graph of the main channel,
voltage for voltage mode or current for current mode.
•
There is no difference between programming and real output waveform, as long as
programmed Limits are not exceeded and the load is resistive. The programming
waveform representation does not taking into account the interaction between set-
tings and load.
•
The graph timing is automatically selected for the best waveform representation.
•
Because the BOP unit is not an oscilloscope, the waveform representation is
sometimes very sketchy, especially if there is a large difference between the timing
of two adjacent segments or for a reduced number of repetitions of high frequency
waveform. Also, synchronization is difficult for low frequency waveforms.
Remote: When using LIST commands for waveform creation/ execution, the LCD dis-
plays the actual or real waveform graphs of the main and limit channel, voltage & cur-
rent protection limit for voltage mode and current & voltage protection limit for current
mode. Main and Limit graphs are not phase correlated.
•
In order to get a meaningful representation, the graph timing must be chosen prop-
erly. It is recommended that the first value higher than total waveform time be cho-
sen from the 12 time selections, spread from 0.04 Second to 75 Seconds.
Frequency:
Not applicable to Level
Range (Hz)
0.001 to 443
Sine, Triangle
0.02 to 532
±Ramp
0.02 to 1000
Square
Programming Resolution (Hz)
0.001
Sine, Triangle
0.01
Ramp, Square
Accuracy
1.5% of Frequency
Sine, Triangle, Square, ±Ramp
Period (applicable to Level only)
Range (Seconds):
0.0005 TO 1.9999 (local front panel)
0.0005 to 5.0000 (remote interface)
Resolution:
0.0001
Accuracy:
1.5% of Time Duration
Amplitude Range
Main Channel
Voltage (Volts p-p)
0 to 2 x EO
NOM
Sine, Triangle, Square, ±Ramp
Current (Amperes
p-p)
0 to 2 x IO
NOM
Sine, Triangle, Square, ±Ramp
Protection Limit Channel . Current, bipolar
(Amperes)
0 to IO
NOM
(set once for all segments)
Voltage, bipolar
(Volts)
0 to EO
NOM
Offset Voltage
(Volts)
–EO
NOM
to +EO
NOM
Applies to offset of sine, triangle, ±ramp, and
square waveforms and to Level waveform
Amplitude.
Current (Amperes)
–IO
NOM
to +IO
NOM
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Summary of Contents for BOP-ME 1KW
Page 2: ......
Page 20: ...xii BOP 1K 091719 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Page 42: ......
Page 64: ...2 22 BOP HIPWR 091719 FIGURE 2 11 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Page 65: ...BOP HIPWR 091719 2 23 FIGURE 2 12 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Page 76: ......
Page 161: ...BOP HIPWR 091719 3 85 FIGURE 3 29 STATUS REPORTING STRUCTURE...
Page 164: ......