MIX 04 (694 444 64)
Kendrion Kuhnke Automation GmbH
364
17 May 2021
0x313f AI/AO Error Code
Object Code
Variable
Sub
0x00
Name
AI/AO Error Code
Data Type
UNSIGNED16
Access
ro
Defaultvalue
PDO Mapping
optional, TPDO only
Accessname
AI/AOErrorCode
See table object 0x1003 Pre-defined error field
0x3201 AI/AO DeviceControl
Object Code
Variable
Sub
0x00
Name
AI/AO DeviceControl
Data Type
UNSIGNED16
Access
rw
Defaultvalue
PDO Mapping
optional, RPDO only
Accessname
AI/AODeviceControl
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RES
RES
0 = no action
1 = Reset Device