Kendrion Kuhnke Automation GmbH
Mix 04 (694 444 64)
357
17 May 2021
Accessname Enc2DigitalInterfaceConfig.Enc2Encoder:Mode
Sub
0x03
Name
Enc2 Encoder: Index level
Data Type
UNSIGNED8
Access
ro
Defaultvalue 0
PDO
Mapping
no
Accessname Enc2DigitalInterfaceConfig.Enc2Encoder:Indexlevel
Sub
0x04
Name
Enc2 SSI: Use grey code
Data Type
UNSIGNED8
Access
ro
Defaultvalue 0
PDO
Mapping
no
Accessname Enc2DigitalInterfaceConfig.Enc2SSI:Usegreycode
Sub
0x05
Name
Enc2 Event Counter: Sensitivity
Data Type
UNSIGNED8
Access
ro
Defaultvalue 0
PDO
Mapping
no
Accessname Enc2DigitalInterfaceConfig.Enc2EventCounter:Sensitivity
Object for configuration of the counter/ encoder interface
Subindex 01 (Encoder: Level)
0 HTL (default)
1 TTL
2 RS422
Subindex 02 (Encoder: Mode)
0 Multiturn Encoder, no Index (default)
1 Single Turn Encoder
Subindex 03 (Encoder: Index level)
0 Reference on rising edge (default)
1 Reference on falling edge
3 Reference on both edges
Subindex 04 (SSI: Use grey code)
0 Straight binary (default)
1 Grey coded binary