Kendrion Kuhnke Automation GmbH
Counter / Encoder (694 454 53)
281
17 May 2021
Accessname
Enc1SpeedParameters.Enc1Dividervalue
Sub 01:
4= Use Object 0x600B
Sub 02:
Integration time in [ms]
Sub 03:
Conversion factor for velocity calculation, result in 0x6030
Sub 04:
Conversion devider for velocity calculation, result in 0x6030
0x6500 Enc1 Operating Status
Object Code
Variable
Sub
0x00
Name
Enc1 Operating Status
Data Type
UNSIGNED16
Access
ro
Defaultvalue
PDO Mapping
no
Accessname
Enc1OperatingStatus
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DIR
Bit 3 DIR
0 = Clockwise
1 = Counter clockwise
0x6800 Enc2 Operating Parameters
Object Code
Variable
Sub
0x00
Name
Enc2 Operating Parameters
Data Type
UNSIGNED16
Access
rw
Defaultvalue
PDO Mapping
no
Accessname
Enc2OperatingParameters
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DIR
Bit 3 DIR
0 = Clockwise
1 = Counter clockwise