A.7 Technical data, step-up choke
For size
BG5
BG6a
For device
SO84.040
SO84.076
SO84.115
SO84.170
Rated AC current
3 x 40 A
3 x 76 A
3 x 115 A
3 x 170 A
Supply voltage
3 x 400 VAC ... 3 x 480 VAC
Designed for active
power (step-up opera-
tion 650 VDC/770 VDC)
26 kW
50 kW
75 kW
110 kW
Power dissipation
at 100 % duty factor
225 W
440 W
400 W
930 W
Frequency
50/60 Hz
Protection
IP00, installation in a switch cabinet necessary
Temperature sensor
KTY84-130
Power connections
Cable cross-section
(flexible without /
with ferrule)
1.5...16
mm
2
1.5...16
mm
2
(AWG 18...
AWG 6)
2.5...35
mm
2
2.5...35
mm
2
(AWG 12...
AWG 0)
2.5...35
mm
2
2.5...35
mm
2
(AWG 12...
AWG 0)
16...120
mm
2
16...95
mm
2
(AWG 4...
kcmil 250)
Tightening torque
1.5...2.4 Nm
(13.2...21.2 lb-in)
4...5 Nm
(35.4...44.2 lb-in)
4...5 Nm
(35.4...44.2 lb-in)
12...20 Nm
(106.2...177 lb-
in)
KTY sensor
Cable cross-section
(flexible with ferrule)
0.5...2.5 mm
2
(AWG 30...AWG 12)
Tightening torque
0.4...0.8 Nm (3.5...7.0 lb-in)
Table A.18 Technical data, step-up choke
Mechanical conditions
ServoOne
Vibration limit in transit
As per EN 61800-2, IEC 60721-3-2 class 2M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s²]
2 ≤ f < 9
3.5
Not applicable
9 ≤ f < 200
Not applicable
10
200 ≤ f < 500
Not applicable
15
Shock limit in transit
As per EN 61800-2, IEC 60721-3-2 class 2M1
Drop height of packed device max. 0.25 m
Vibration limits for the
system
1)
As per EN 61800-2, IEC 60721-3-3 class 3M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s²]
2 ≤ f < 9
0.3
Not applicable
9 ≤ f < 200
Not applicable
1
1) Note: The devices are only designed for stationary use.
Table A.17 Mechanical conditions, ServoOne
NOTe:
According to EN ISO 13849-2 the switch cabinet must have IP54 protection
or higher on using the STO (Safe Torque OFF) safety function.
NOTe:
The supply unit and the DC drive controllers must not be installed in areas
where they would be permanently exposed to vibration.
Appendix
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...