Operation Manual ServoOne Supply Unit
27
ID no.: 1101.21B.6-00 Date: 04/2020
3.8 Mounting mains filter
1.
Arrange the components such that adequate air circulation and heat dissipation is
ensured.
Pay attention to the bending radius of the connection cables.
For dimensional drawings/hole spacing see Figure 3.20 and Table 3.5.
2.
Mount the mains filter on the backing plate.
The thread surface area will provide good contact. The contact area must be bare
metal.
3.8.1
Dimensions
For size
BG5
BG6a
BG7
For device
SO84.040 SO84.076 SO84.115 SO84.170 SO84.375 SO84.540
Type
FFU
3 x 56 K
FFU
3 x 80 K
FFU
3 x 130 K
FFU
3 x 180 K
FN 3359-
400-99
FN 3359-
600-99
B (width)
85
80
90
130
260
260
H (height)
250
270
270
380
300
300
T (depth)
90
135
150
180
115
135
A
60
60
65
102
235
235
C
235
225
255
365
120
120
G Ø
5.4
6.5
6.5
6.5
12
12
Mounting screws
M5
M6
M6
M6
M10
M10
Weight [kg]
1.9
2.6
4.2
6.0
10.5
11
All dimensions in mm and not including terminals/connectors
Table 3.5 Dimensions, mains filter
NOTe:
The mains filter is only intended for installation in a switch cabinet because
the filter is designed in degree of protection IP00 without protection against
touching.
A1
H
A
B
ØD1
ØD2
T
Figure 3.19 Dimensional drawing, input choke, based on BG7 as an example (SO84.375)
Mechanical installation
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...