Operation Manual ServoOne Supply Unit
71
ID no.: 1101.21B.6-00 Date: 04/2020
6
Diagnostics
6.1
Device states
The device states can be read on the 7-segment display (D1, D2).
Display
Meaning
Parameter
System states
Device in reset state
Self-initialisation on device startup
(Start)
1)
Not ready to switch on
(no DC link voltage)
(NotReady-
ToSwitchOn)
1)
Switch on disabled (ENPO not set )
(DC link precharged to ideal DC link voltage, power stage
not ready)
(SwitchOnDisabled)
Ready to switch on (ENPO set)
(power stage ready)
(ReadyToSwitchOn)
Switched on
(DC link voltage will be increased to setpoint / soft start
active)
(SwitchedOn)
Supply unit ready
(setpoint for the DC link voltage reached)
(OperationEnabled)
Fault reaction active
(FaultReactionActiv)
Fault (for list of faults see chap. 6.2, p. 72)
(Fault)
1) This not a "safe indication" in the context of EN 61800-5-2.
Table 6.1 Device states
NOTe:
The safety function STO (Safe Torque OFF) is not required for the ServoOne
supply unit, as no motors are connected. To be able to start the supply unit, a
jumper must be placed between X4/14 and X4/22.
If this jumper is forgotten, there is a flashing point on the device display. The
safety function STO is used for ServoOne DC axis controllers.
6.1.1
Errors
If there is an error, the following is displayed alternately: ER > 02 > 05 * ER > 02 > 05 ...
Display
Meaning
Explanation
Error
ER = "Malfunction"
Error name:
02 = "Error in the parameter list"
Error description:
05 = "Function for checking the actual parameter list"
Table 6.2 Indication if there is an error
NOTe:
The errors can be reset according to their programmed reaction (ER) or only
by means of a 24 V reset (X9/10) (ER.).
NOTe:
Errors marked with a point can only be reset once the cause of the error has
been rectified.
Diagnostics
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...