Operation Manual ServoOne Supply Unit
72
ID no.: 1101.21B.6-00 Date: 04/2020
Error
number
Error
location
Error text
06
Overtemperature PTC
00
Unknown error
01
PTC temp. to high
02
PTC DIN2 error detected (shortcut, resistance smaller 50 Ohm)
03
PTC DIN3 error detected (overtemperature, resistance higher than
3500 Ohm)
04
PTC DIN1 error detected (hysteresis after over temperature, resistance
higher than 1650 Ohm)
07
Overtemperature powerstage cooler
00
Unknown error
01
Overtemperature inverter detected
08
Overtemperature PSU interior
00
Unknown error
01
Overtemperature PSU interior detected
09
Error grid
00
Unknown grid error
01
Grid frequency out of range
02
Grid voltage out of range
03
Timeout during synchronization
10
Error I2t power amplifier
00
Unknown error
01
I2t power amplifier detected
11
External error at digital input detected
00
Unknown external error
01
External error triggering at digital input
12
Error in CAN option
00
Unknown CAN option error
01
CAN option: BusOff error
02
CAN option: Guarding error
Table 6.3 Error list
6.2 Error list
Error messages (error number, error location, error text) for the supply unit are listed in
the following table. In there is an error, the display on the supply unit changes cyclically
between the indications "Er", ">Error number<", ">Error location<". The error messages
can be acknowledged by switching the input ENPO (X4/10).
Error
number
Error
location
Error text
01
Runtime error
00
Unknown runtime error
02
Error in parameter list
00
Unknown runtime error
01
Parameter initialisation failed
02
Parameter virgin initialisation failed
03
Error in parameter saving routine
04
Error in paralist while adding a new parameter
05
Parameter check failed
06
Parameter ID is multiply defined
07
PowerStage data are corrupt
08
Device cannot be used in this voltage level
03
Under voltage
00
Unknown error
01
Undervoltage detected
04
00
Unknown error
01
Overvoltage detected
05
Over current
00
Unknown error
01
Overcurrent (hardware) detected
02
Overcurrent (software) detected
03
Overcurrent (software) detected
Diagnostics
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...