Operation Manual ServoOne Supply Unit
29
ID no.: 1101.21B.6-00 Date: 04/2020
4
Electrical installation
4.1 Before you start
It is imperative you pay attention to the following warnings and safety instructions prior to
and during installation.
DANGeR!
Risk of injury due to electrical power!
• Carelessness will result in serious injuries or death.
Never make or disconnect electrical connections while they are electrically live! Before making
any change
the device is to be disconnected from the mains. Even 30 minutes after switching off the
mains supply dangerously high voltages of ≥50 V may still be present (capacitor charge). The
discharging time depends on the controllers connected to the multi-axis system. So check that
electrical power is not present!
Only once the DC link voltage has dropped to less than 50 V DC (to be measured on size BG5
and BG6 at terminals X11/L+ and X11/L- and on size BG7 at terminals X11/ZK+ and X11/ZK-)
are you allowed to work on the device.
Any existing additional DC link connections as well as the connections for all components in
the mains input area are to be checked in relation to each other and in relation to earth to
ensure they are not carrying any electrical power. If necessary, all cable connections are to be
discharged using suitable means.
Warning!
Risk of injury due to electrical power!
• Carelessness may result in serious injuries or death.
A dangerous voltage may be present at the device, even if the device does not emit any visual
or audible signals/indications, e.g. for BG5 and BG6a: with mains voltage on terminal X12 or
X21 switched on and no control 24 V on X9, X10; or for BG7: with mains voltage on
terminal X12 or X45 and no control 24 V on X44. So check that electrical power is
not present!
WARNING!
Risk of injury due to hot surfaces on the device!
•
Carelessness may result in serious burns.
The device and especially the heat sink heat up significantly during operation and can reach
temperatures of up to 100 °C. The chokes connected also heat up during operation and can
reach temperatures of up to 145 °C. Prior to starting work, make sure the device has cooled
down.
On touching there is a risk of burns to the skin. For this reason provide protection against
touching.
During mounting maintain an appropriate distance to neighbouring assemblies.
NOTe:
On installing the ServoOne multi-axis system, it is imperative the operation
manual for the DC axis controllers is also followed.
Electrical installation
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...