Operation Manual ServoOne Supply Unit
81
ID no.: 1101.21B.6-00 Date: 04/2020
A.6 Ambient conditions
Ambient conditions
ServoOne
Protection
IP20 except terminals (IP00)
Accident prevention reg-
ulations
As per the local regulations (in Germany e.g. BGV A3)
Installation altitude
Up to 1000 m above MSL, over 1000 m above MSL with power
reduction (1 % per 100 m, max. 2000 m above MSL)
Pollution degree
2 (according to EN 60664-1)
Type of mounting
Built-in unit, only for vertical mounting in a switch cabinet with
min. IP4x protection, when using STO safety function min. IP54.
Table A.15 Ambient conditions
Climatic conditions
ServoOne
In transit
As per EN 61800-2, IEC 60721-3-2 class 2K3
1)
Temperature
-25 °C to +70 °C
Relative atmospheric
humidity
95% at max. +40 °C
In storage
As per EN 61800-2, IEC 60721-3-1 classes 1K3 and 1K4
2)
Temperature
-25 °C to +55 °C
Relative atmospheric
humidity
5 to 95%
In operation
As per EN 61800-2, IEC 60721-3-3 class 3K3
3)
Temperature
-10 °C to +40 °C, up to 55 °C with power
reduction (2 % per °C)
Relative atmospheric
humidity
5 to 85 % without condensation
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70 °C for example, that the relative atmospheric humidity
may only be max. 40%.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative atmospheric humidity
stipulated in the table must not occur simultaneously.
3) The absolute humidity is limited to max. 25 g/m³. That means that the maximum values for temperature and relative atmos-
pheric humidity stipulated in the table must not occur simultaneously.
Table A.16 Climatic conditions, ServoOne
A.5 Dynamic temperature monitoring
Should the coolant flow rate collapse or not become established, the power stage could
overheat. For this reason the drive controllers BG5 and BG6a are equipped with dynamic
monitoring of the heat sink temperature and drive controller BG7 is equipped with static
monitoring or the temperature of the power stage; this monitoring shuts down the drive
controller in the event of overtemperature.
Independent of the temperature gradient, the drive controller shuts down at the follow-
ing heat sink temperature:
Size
BG5
BG6a
BG7
Device
SO84.040
SO84.076
SO84.115
SO84.170
SO84.375
SO84.540
Shutdown of the device
at a heat sink temper-
ature
65 °C
90 °C
Table A.14 Dynamic monitoring of the heat sink temperature
Appendix
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...