MS48IP Programming Guide
86
A technician can use all of the program codes (except for the LCR) that are
available in this guide. Additionally, s/he can activate the user and operator features
below during the remote programming:
1. The night mode
2. Time setting
3. Date setting
4. Common pool entry
5. Parameter download
6. Call Listing
7. All Call Listing / Stop Listing
8. Total Cost Listing
9. Call Record Clear
10. Remote Follow Me
11. Line Access
Since the line used for the remote programming has been automatically
marked as DISA, the technician can access another line only by dialing an
extension number and entering the corresponding password of that
extension.
If no number is dialed within 15 seconds, after another line is accessed,
then the line, which has already been accessed, is automatically released.
The external call, which the technician will make, can take at most 50
seconds.
12. Calling an extension
While using this facility, if the extension of the system hangs up, the line is
not released but the technician receives the special dial tone for remote
programming, so that s/he can continue with the remote programming of
the system.