MS48IP Programming Guide
56
Line Parameters:
This program assigns various parameter values for a line.
8 0 0 D A P R S T ( D a y m o d e )
8 0 0 D A ( N i g h t M o d e )
Parameters
D
:
The line access code
A
:
The access code of the extension that will be rung by the line.
P
:
0
The line can be accessed both by dialing 9 and by selective line
access as well.
:
1
No access to the line by dialing 9, only selective line access.
R
:
0
Line call authorities of extensions requesting line access are checked.
:
1
Line call authorities of extensions requesting line access are not
checked.
S
:
0
No fax router mode is active on the line
:
1
Fax router mode 1 is active
:
2
Fax router mode 2 is active
T
:
0
Auto answer mode of EVM module is active
:
1
When the system in night mode, even the ACD is in service, the EVM
services are not used for the line and when the ACD is out of service
and the Night Mode Greeting message is recorded, the automatic
answering service is not used.
Default Value
A=Operator, P=0, R=0, S=0 and T=0 for all lines.
Notes
1. P = 1 is especially useful when T is connected to one of the extensions of
another exchange to form a tie line.
2. R = 1 is especially useful when T is connected to one of the extensions of
another exchange to form a tie line.
3. If S = 0, then A defined in the night mode is the night ringing extension. Thus
different ringing extensions for day mode and night mode can be defined.